iGuard
provides easy-access terminals for connections to external controls, including Door
Strikes, Door Sensor, Door Open Switch, and External Alarm.
Power (12V DC)
Terminals #1 (ground) & #2 (+12V). The power requirement is 12V
DC, 200mA (idle) 800mA (peak). Since most of the door strikes require
the same 12V DC power supply, iGuard may share the same power supply with
the door strike.
Door Strike (Optional)
Terminals #3-5 (3-4 Normal Open, 4-5 Normal Close). These terminals are
connected directly to the internal relay, rating at 12V / 5A. If the door strike is
within this current limit, it can be directly connected to these terminals. If the
system is used solely for Time Attendance System, these terminals can be left open.
Door Sensor (Optional)
Terminals #6-7. It provides iGuard the current status of the door (open /
close). If the door is left open for over 10 seconds, iGuard will generate beep
sounds to alert the people.
Door Open Switch (Optional)
Terminals #8-9. An optional door switch can be connected to these terminals.
It is used to open the door remotely, such as opening the door from the inside of
the business premises, or from the reception area.
External Alarm (Optional)
Terminals #10-11. This is used for optional external alarm. If the case
of the device is forced open during operation (such as a break-in), an internal sensor
will trigger this connection, and it will sound the external alarm.
¡@ |